Abstract

Electrostatic charges on individual spray droplets were measured using a refined form of the Millikan oil drop method. The measurement system consisted of three main sections; a droplet generation cell, a settling column and a charge measurement chamber. The trajectories required for calculation of charge were determined using a high-speed motion analyzer coupled to a long-focal-length microscope. Charges on droplets were manipulated by the addition of surface-active agents into the spray solution. Droplet charge was a function of the type and concentration of the surfactant added. For ionic surfactants, it showed a maximum at low surfactant concentrations, decreased with further surfactant addition and was constant after the CMC. The charge on cationic surfactants was always more than that observed with the anionic surfactants. Nonionic surfactants displayed a steady increase in droplet charge with increasing concentration. The charges were lower compared to the ionic surfactants.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.