Abstract

Electropolishing treatment (EP) can be used to remove the biofilm formed on AISI-304 stainless steel surface and protect it against bacterial colonization. High levels of both smoothness and brightness of AISI-304 stainless steel surfaces can be attained by using electropolishing technique, where the sample was fixed as anode and a suitable current was applied into electrolytic cell containing H3PO4. AISI-304 stainless steel was exposed to stabilized mixed culture of sulfate reducing bacteria (SMC-SRB) under different conditions as, temperature, pH, salinity, incubation time and inoculum size. The present study recorded the main indicators of bacterial activity such as S−−, Fe++, most probable number (MPN) of SRB and weight loss (corrosion rate) by milinches per year (mpy). The results revealed that the bacterial counts were obviously decreased under all conditions of bacterial biofilm formation after electropolishing treatment.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call