Abstract

Intraoperative monitoring of the motor evoked potential (MEP) during cerebral aneurysm surgery has been widely used to confirm surgical safety. In this study, we retrospectively analyzed the influence of the MEP amplitude resulting from temporal occlusion of the parent artery, and appropriate judgement in the surgery was discussed. Ten patients underwent temporal occlusion of the parent artery during aneurysm surgery, and five of these patients showed a decrease in the MEP amplitude following temporal arterial occlusion. Clinical factors in patients with and without MEP decrease were compared. The time gap between the surgical procedure and the MEP change and recovery was then investigated. A decrease in the MEP amplitude caused by temporal occlusion had a significantly higher occurrence compared with permanent clip failure. The time from the release procedure to MEP amplitude recovery was relatively longer than the time from the occlusion procedure to the decrease in MEP amplitude. The time from release procedure to MEP amplitude recovery showed a weak correlation with the parent artery occlusion time. There is a time gap between releasing the temporal arterial occlusion and MEP recovery that is similar to temporal parent arterial occlusion and the MEP decrease. The cause of MEP amplitude should be judged carefully, and influence of parent artery temporal occlusion should be taken into consideration during aneurysm clipping.