Abstract
Identifying the location, the spatial extent and the electrical activity of distributed brain sources in the context of epilepsy through ElectroEncephaloGraphy (EEG) recordings is a challenging task because of the highly ill-posed nature of the underlying Electrophysiological Source Imaging (ESI) problem. To guarantee a unique solution, most existing ESI methods pay more attention to solve this inverse problem by imposing physiological constraints. This paper proposes an efficient ESI approach based on simulation-driven deep learning. Epileptic High-resolution 256-channels scalp EEG (Hr-EEG) signals are simulated in a realistic manner to train the proposed patient-specific model. More particularly, a computational neural mass model developed in our team is used to generate the temporal dynamics of the activity of each dipole while the forward problem is solved using a patient-specific three-shell realistic head model and the boundary element method. A Temporal Convolutional Network (TCN) is considered in the proposed model to capture local spatial patterns. To enable the model to observe the EEG signals from different scale levels, the multi-scale strategy is leveraged to capture the overall features and fine-grain features by adjusting the convolutional kernel size. Then, the Long Short-Term Memory (LSTM) is used to extract temporal dependencies among the computed spatial features. The performance of the proposed method is evaluated through three different scenarios of realistic synthetic interictal Hr-EEG data as well as on real interictal Hr-EEG data acquired in three patients with drug-resistant partial epilepsy, during their presurgical evaluation. A performance comparison study is also conducted with two other deep learning-based methods and four classical ESI techniques. The proposed model achieved a Dipole Localization Error (DLE) of 1.39 and Normalized Hamming Distance (NHD) of 0.28 in the case of one patch with SNR of 10 dB. In the case of two uncorrelated patches with an SNR of 10 dB, obtained DLE and NHD were respectively 1.50 and 0.28. Even in the more challenging scenario of two correlated patches with an SNR of 10 dB, the proposed approach still achieved a DLE of 3.74 and an NHD of 0.43. The results obtained on simulated data demonstrate that the proposed method outperforms the existing methods for different signal-to-noise and source configurations. The good behavior of the proposed method is also confirmed on real interictal EEG data. The robustness with respect to noise makes it a promising and alternative tool to localize epileptic brain areas and to reconstruct their electrical activities from EEG signals.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.