Abstract
Graphene coating on pure copper substrate was successfully prepared by electrophoretic deposition (EPD) technology. The effects of deposition parameters on the coating structure and its corrosion resistance in 3.5 wt% NaCl solution were investigated. The results show that the open circuit potential (OCP) of the coating sample (−0.107 V) is about 0.1 V higher than that of the substrate (−0.199 V), and the corrosion current density (Icorr) decreases by an order of magnitude. Moreover, too long deposition time or too high deposition voltage will cause defects in the deposited coating, resulting in the weakening of corrosion resistance. The optimum deposition condition is 30 V for 40 min.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.