Abstract

The isotropic Compton profile of mercury has been measured, using 661.65 keV gamma-rays from a 20 Ci 137Cs source. To extract the true experimental Compton line shape, besides the usual systematic corrections we have incorporated for the first time the background correction due to bremsstrahlung radiation generated by photo and Compton electrons. Theoretical computations have been carried out, using the renormalised-free-atom (RFA) for the electron configuration 4f145d106s2 and free electron models. It is found that the present experimental data with bremsstrahlung background correction are in better agreement with the RFA calculations. This work suggests the incorporation of the bremsstrahlung background correction in Compton scattering experiments of heavy materials using high-energy gamma-ray sources.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.