Abstract

A sensitive and specific electron-capture detector GLC method capable of detecting picogram quantities of tocainide, a lidocaine analog, in biological fluids was developed. This method consists of extracting the compound into methylene chloride and derivatizing with heptafluorobutyric anhydride to form the monoheptafluorobutyryl derivative. The derivative formation was confirmed by GLC-mass spectrometry. Quantitative estimation was performed using l-bromonaphthalene as an internal standard. The minimum detectable level by the electron-capture method was approximately 30pg/injection as opposed to approximately 3ng/injection with a flame-ionization detector. Linear response was observed in the range from 50pg to 3ng using an electron-capture detector. No interference from endogenous substances was observed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.