Abstract
A hot plasma can be analysed by means of soft-X-ray fluxes using various absorbers. In the first part of the paper, the method of calculation of the flux as a function of Te, Zeff, ne and their profiles is given. The problem of relativistic corrections in the evaluation of the Gaunt factor is also considered. As an example, in a 200-kA discharge in TFR, the measured fluxes are compared to those calculated for a Maxwellian electron distribution function. From this comparison, the electron temperature is determined and information on the impurity content in the plasma is obtained, in agreement with other independent measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.