Abstract

We looked at the electron microscopic appearances of the corneal endothelium following neodymium:YAG (Nd:YAG) laser iridotomy in a patient with a shallow anterior chamber. An area of denuded endothelial cells approximately 500 microns in diameter was produced when no contact lens was used. The area of cell loss was reduced by approximately 50% when an Abraham YAG goniolens was used. We conclude that the use of a positive plus contact lens can help minimize cell loss following Nd:YAG laser iridotomy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.