Abstract

In this article we present the development of a new diagnostic capable of determining the electron density in the divertor volume of ASDEX Upgrade (AUG). It is based on the spectroscopic measurement of the Stark broadening of the Balmer lines. In this work two approaches of calculating the Stark broadening, i.e. the unified theory and the model microfield method, are compared. It will be shown that both approaches yield similar results in the case of Balmer lines with high upper principal quantum numbers n. In addition, for typical AUG parameters the influence of the Zeeman splitting on the high n Balmer lines is found to be negligible. Moreover, an assumption for the Doppler broadening of Tn = 5 eV, which is the maximum Frank–Condon dissociation energy of recycled neutrals, is sufficient. The initial electron density measurements performed using this method are found to be consistent with both Langmuir probe and pressure gauge data.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.