Abstract
Electron cyclotron heating (ECH)-assisted startup experiments have been performed in JT-60U. The breakdown loop voltage was successfully reduced from 25 to 4 V (=0.26 V m−1) by 200 kW ECH. This is lower than the 0.3 V m−1, which corresponds to the maximum electric field in ITER. Parameter scans of ECH power, prefill pressure, resonance position and polarization were carried out. The sensitivity of the breakdown to polarization and resonance position was observed. A prefilling gas pressure scan showed that the initial breakdown density increases with prefill pressure when it is is lower than 8 × 10−5 Torr. Higher harmonic ECH was also attempted. The second harmonic ECH-assisted startup was possible with higher ECH power injection. However, the third harmonic ECH-assisted startup was not successful.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.