Abstract

Electron cyclotron current start-up as a scheme to initiate ohmic discharges has been investigated with two circuits of open and shorted primary windings of transformer. The experimental results indicate that we can achieve the saving of equivalent flux and the reduction of starting voltage in the initial phase for the two circuits in fundamental frequency resonance region.