Abstract

In this work, electron beam was used for butt brazing of austenitic stainless steel with grade 2 titanium. Due to its low solidus temperature and high silver content, AWS BAg-21 filler containing Ag, Cu, Sn and Ni was selected. The joints were brazed with a defocused oscillating beam using offset. The resulting brazed joints were subjected to static tensile testing, light microscopy, scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) analysis and hardness tests. By using appropriate parameters it was possible to reduce the phenomenon of diffusion of titanium atoms into the joint, which improved the properties of the obtained joints. The maximum tensile strength obtained was 244.2 MPa.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.