Abstract

This study examined muscle fatigue and discomfort in a confined-space welding operation at a shipyard. Surface electromyography (SEMG) was recorded from seven upper extremity and torso muscles of welders welding in a mock-up of the work environment. Following spectral transform of the SEMG data the percentage of the total signal power in the 10–30 Hz frequency band was compared over time during welding. For the conventional stick electrode welding process (SMAW) several muscles exhibited an increase in the percent of the total signal power in the low-frequency band. Fewer muscles exhibited this fatigue-related spectral density shift with a wire welding process (FCAW) the shipyard has considered adopting. This finding suggests that localized muscle fatigue may be reduced by a change to the wire welding process. Subjectively reported discomfort was generally low for both processes, but confirmed the finding that discomfort in the low back and shoulder regions is experienced in this welding operation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.