Abstract
AbstractElectromigration reliability of a GMR spin valve device has been investigated at elevated temperatures at various DC current densities. Significant degradation of the magnetoresistance was observed when the current density was higher than 20 MA/cm2. Either the electromigration induced damage or the rotation of the magnetization vector of the Mnlr anti-ferromagnetic layer are possible mechanisms of degradation. Furthermore, significant voiding caused by electromigration and thermal gradient induced atomic motion was observed at current densities higher than 35 MA/cm2. High-resolution temperature distribution measurements by scanning thermal probe microscopy revealed the existence of a huge temperature gradient of 106°C/cm, which is a strong driving force for atomic diffusion.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.