Abstract

Heated tobacco products and electronic cigarettes are considered as alternatives to traditional tobacco cigarettes. However, it is crucial to monitor and compare the nicotine concentration in inhaled aerosols from these tobacco products, owing to the addictive nature and adverse effects of nicotine on human health. This study aimed to provide an electromembrane extraction (EME) combined liquid chromatography method to extract and determine nicotine in different inhaled aerosols. EME showed high extraction efficiency, selectivity, and sample clean-up capability. Under the optimal parameters, the linear range for nicotine was 0.1–200 mg L−1 (r2 > 0.9998), and the limit of detection was 0.02 mg L−1. Good precision was obtained with the intra- and inter-day relative standard deviations of 2.2 % and 2.8 %, respectively. Repeatability was satisfactory (<7.7 %), and recoveries ranged from 81.0 % to 112.8 %. Finally, this method has been successfully used for the determination and comparison of nicotine in aerosols from these three tobacco products.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.