Abstract
Mechanical fatigue of lead zirconate titanate ceramics when both an ac electric field and mechanical stress were applied to the specimen was investigated. Fatigue strengths under an ac electric field degraded compared with the fatigue strengths under short-circuit conditions while the slope of the S-N curve was the same as that under the short-circuit condition. The reason for the degradation of fatigue strength under an ac electric field is considered to be the microscopic internal stress caused by the electric-field-induced strain. Degradation of fatigue strengths under an ac electric field became larger when the electric field became bipolar even though the amplitude of the field was the same. The reason for the dependence of fatigue strength under an ac electric field on the applied field polarity is considered that the internal stress became large when the ac electric field became bipolar.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.