Abstract
To depress the vibration and meandering of a thin steel plate in a steel making plant, electromagnets are applied to the plate. According to the results of numerical calculation, the different pole arrangement is superior to the same pole arrangement for the vertical position control, though the same pole arrangement is superior to the different pole arrangement for the lateral position control. There is no significant difference in the electromagnetic forces obtained at room temperature as compared to 700/spl deg/C. However, the investigation shows that the smallest electromagnetic forces are obtained at the 765/spl deg/C.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.