Abstract

The authors show that the mass velocity profile in a detonation wave can be measured with electrode geometry, and they discuss the conditions necessary for the simultaneous measurement of mass velocity and electrical conductivity. A diagram illustrates the experimental scheme for measuring these values in stainless steel tubes equipped with differentiating magnetic sensors. Charts present data on dimensionless mass velocity profiles and pressure profiles behind detonation fronts in gases.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.