As thick steel tubes of small diameter are used in heat exchangers in various electric power plants and petrochemical plants, the inspection of these steel tubes is very important. The outer side defects are often observed on these small steel tubes. Moreover, since these steel tubes in heat exchangers are stored as a bundle, it is necessary to inspect the outer side defects of these steel tubes from the inside of the tube. In this paper, the electromagnetic inspection method using a direct current (dc) magnetic field and an alternating current (ac) magnetic field is proposed. The behavior of flux in steel is examined using 3-D finite-element method (FEM) taking account of hysteresis (minor loop) and eddy current. It is shown that the detection of outer side defect is possible by the differential permeability of minor loop of which the position on the hysteresis loop is affected by the existence of the defect.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.