Abstract

Economizers are widely employed in the boiler system to increase efficiency and save energy. However one prominent problem is the severe corrosion of economizer due to the decrease of the exhaust temperature of boiler. Ni–P/Cu/Ni-P multilayer coatings, which could effectively improve the corrosion resistance of the facilities in economizer, are introduced in the present work. The three-layer coatings, whose composition is Ni–P/Cu/Ni-P from substrate to surface, were prepared using dual baths (acidic hypophosphite-reduced electroless nickel bath and acidic replacement electroless copper bath). The corrosion resistance of the coatings was evaluated by porosity and electrochemical tests. The results of porosity evaluation show that all the multilayer coatings performed better than the single-layer coatings of similar thickness. Similarly, The electrochemical tests showed lower corrosion current density for the multilayer coatings in 3.5 wt.% NaCl aqueous solutions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.