Abstract

The golden hamster (Mesocricetus auratus) is a popular laboratory animal and is used in a multitude of behavioural studies. However, it has been shown that it suffers from different forms of hereditary hydrocephalus, which may result in behavioural changes. This prospective study was designed to look into the usefulness of electroencephalography (EEG) measurements in the diagnosis of hydrocephalus in hamsters. The EEGs of the hydrocephalic hamsters were evaluated double-blind and showed a high-voltage slow wave activity, with a fast activity superimposed onto it. This pattern has already been well described in other hydrocephalic species and differed significantly from the EEGs that were obtained from the normal hamsters. It was concluded from our study that a background activity with an amplitude over 50 muV in combination with a frequency of < or =5 Hz was highly indicative of hydrocephalus in young hamsters. We believe that the EEG could be a very useful diagnostic tool in the screening for hydrocephalus in hamsters.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.