Abstract
The electroencephalographic (EEG) responses of 31 bulls (zebu crossbred cattle) stunned with either pneumatically powered Jarvis penetrating (PCB) or non-penetrating captive bolt (NPCB) was examined. Animals were organized into two treatment groups: PCB (n = 20); and NPCB (n = 11) stunning, both using airline pressures of 220 psi (1517 kPa). All bulls shot with PCB (n = 20/20) had patterns of EEG activity that were inconsistent with consciousness. Of the cattle shot with NPCB 82% (n = 9/11) showed waveforms suggesting complete unconsciousness. After stunning two NPCB bulls had periods of normal EEG activity and maintenance (Ptot, delta, theta, beta) or increased (alpha) spectral power compared to pre-treatment values, indicating incomplete concussion. The study showed that pneumatic PCB stunning was effective in rendering all bulls unconscious, while NPCB was less effective. This highlights the potential animal welfare risks associated with NPCB compared to PCB stunning of mature bulls in commercial abattoirs.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.