Abstract

The application of electrochemical plating method for the deposition of electropositive Ru and electronegative Am was examined. These investigations were aimed on the preparation of sealded radiation sources of106Ru used in treatment of intraocular tumours, and241Am used for ionization purposes. The composition of galvanic baths and process parameters influencing the quality and stability of ruthenium deposites and americium with gold co-deposites were determined. The effect of ageing of the electrolyte on the rate of241Am co-deposition was investigated. From the results obtained it follows that the ageing favours the formation of species affecting the transport of americium towards the cathode. The method of sealing of the sources by means of galvanic deposition of metallic protective layers is described. The galvanic plating technique enables manufacturing of sealed radiation sources of106Ru and241Am.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call