Abstract

AbstractLaser‐induced graphene (LIG) is a promising technology enabling cost‐effective, scalable, and high surface area 3D‐porous graphene electrodes for electrochemical applications. Nitrate in water bodies is a harmful contaminant to humans and the ecosystems. Its detection by electrochemical sensors is challenging due to the interference from nitrite. Herein, for the first time, a LIG‐based electrochemical sensor modified with electrodeposited silver dendrites (EdAg/LIG) without using surfactants is proposed for the detection of nitrate with tunable selectivity and sensitivity. The modified electrode surface is extensively characterized by spectroscopic and electrochemical methods and the underlying mechanism for the formation of dendrites is substantiated. The developed EdAg dendrites/LIG electrode shows excellent sensing properties for the detection of nitrate at pH 2. The interference with nitrite in acidic media is eliminated by implementing a novel strategy to shift the working pH of the electrode to 7. The achieved sensor properties at both pH values surpass other LIG‐based sensors with limit of detection of 0.46 at pH 2 and 5.53 µm at pH 7. The developed sensor also shows good recovery characteristics in mineral, tap, and groundwater across a wide range of concentrations and also demonstrates good stability under temperature fluctuations and deformations.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call