Abstract
Cr (VI) transport through a composite ceramic membrane containing an ion-exchange component, namely xerogel of hydrated zirconium dioxide, was investigated. The diffusion coefficient of Cr (VI) species through the membrane, which has been determined under open circuit conditions, is 1.80 × 10−10 m2 s−1. The transport number of Cr (VI) species through the ceramic membrane was found to rise with increasing voltage and reached 0.17 under “over-limiting current” conditions. On the other hand, the transport of chromate ions through hydrogel of hydrated zirconium dioxide becomes more intensive with a decrease in potential drop through the system involving ion-exchanger bed and ceramic membrane due to decrease in the membrane resistance. The diffusion coefficient of Cr (VI) ions in hydrogel of the inorganic ion exchanger was estimated as 4.36 × 10−12 m2 s−1. A possibility of Cr (VI) removal from a weakly acidic diluted solution using an electro-deionization method was shown: the degree of solution purification was found to reach 50%. The transport of species is realized through both the solution and the ion exchanger.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.