Abstract

The most realistic model for current-to-voltage measurements of electrical impedance tomography is the complete electrode model which takes into account electrode shapes and contact impedances at the electrode/object interfaces. When contact impedances are small, numerical instability can be avoided by replacing the complete model with the shunt model in which perfect contacts, that is zero contact impedances, are assumed. In the present work we show that using the shunt model causes only a (almost) linear error with respect to the contact impedances in modelling absolute current-to-voltage measurements. Moreover, we note that the electric potentials predicted by the two models exhibit genuinely different Sobolev regularity properties. This, in particular, causes different convergence rates for finite element approximation of the potentials. The theoretical results are backed up by two dimensional numerical experiments.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.