Abstract

Electrode material dependence of intense-mode vacuum arc behaviour was systematically investigated by using the Shack-Hartmann method capable of simultaneously visualising two-dimensional electron and metal vapour density distributions from single-shot recordings. The electrode materials studied included Cu, CuCr (Cu75Cr25 wt. %), WC, and AgWC (Ag40WC60 wt. %). A comparison between the Cu and CuCr electrodes showed that the metal vapour densities for the CuCr decreased in an even shorter time scale than for the Cu. In the case of the WC electrodes, the widths of the electron density distributions became narrower as the arc current decreased although the electron densities hardly decreased in the decaying process of the arc current. The density measurements conducted at the late stage of the vacuum arcs demonstrated that the metal vapour densities around the anode were maintained at the highest value for the AgWC among the electrode materials in this study.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call