Abstract

The growth of bacteria in culture was found to produce impedance changes between two metal electrodes which result from changes both in conductivity and electrode impedance. Predominant changes were found in the imaginary impedance component at low frequency. Linear ac impedance characteristics were found in the relation between real and imaginary impedance components before and during bacterial growth. This linear relation is consistent with characteristics of diffusion and electron exchange (oxidation-reduction) at the electrode. The measurement of impedance in this system was limited below 100 Hz by nonlinearity in the voltage-current relation. Bacterial growth was best detected with stainless steel electrodes at low frequency (100 Hz) and including the imaginary component of impedance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.