Treatment of real reactive dyebath effluent comprising of an exhausted reactive dyebath and its sequential rinses with electrocoagulation (EC) using aluminum (Al) and stainless steel (SS) electrodes was investigated. The experimental study focused on the effect of applied current density (22–87 mA/cm 2; at an initial, optimum pH of 5.5) on decolorization and COD removal rates using Al and SS as electrode materials. Results have indicated that the treatment efficiency was enhanced appreciably by increasing the applied current density when Al electrodes were used for EC, whereas no clear correlation existed between current density and removal rates for EC with SS electrodes the treatment efficiency could only be improved when the applied current density was in the range of 33–65 mA/cm 2. It was established that EC with SS electrodes was superior in terms of decolorization kinetics (99–100% color removal after 10–15 min EC at all studied current densities), whereas EC with Al electrodes was more beneficial for COD removal in terms of electrical energy consumption (5 kWh/m 3 wastewater for EC with Al electrodes instead of 9 kWh/m 3 wastewater for EC with SS electrodes).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.