Abstract
In this research electrochemical treatment was used to treat Al-Sin water that feed Banias thermal station boilers for generate electricity. The effect of the operating parameters such as type of electrodes, initial pH,inter electrode distance, electrolysis time and current density on the effectiveness of electrochemical processing were studied in reducing the concentration of total dissolved solids (TDS), NaCl concentration, and electrical conductivity. The experiments were carried out in a batch mode. Results revealed that in the optimum conditions (current density=500A/m2, distance between electrodes =10mm) the total dissolved solids, conductivity, and NaCl concentration were reduced by (97%), (94%) and (92%) respectively after one hour of treatment process by using aluminum electrodes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Association of Arab Universities Journal of Engineering Sciences
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.