Abstract

Corrosion rates of mild steel for long-term immersion were estimated by electrochemical and weight-loss methods. The results showed that application of electrochemical methods yielded erroneous values. The main reason was that, β-FeOOH, produced after long-term immersion with high electrochemical activity in the inner rust layer, exerted significant influence. In electrochemical tests, even small polarization can make β-FeOOH participate in cathodic reaction, which leads to overestimating corrosion rate. In order to confirm it, electrochemical behaviour was studied in aerated and deaerated conditions to investigate the effect of rust layers on reduction reaction. After calibration, the electrochemical measurement result was coincided with the weight loss.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.