Abstract

The effects of alternating current on the galvanic coupling zinc/pipeline steel were investigated in 4 g/L Na2SO4 simulated backfill solution by weight‐loss measurements for 96 hr, electrochemical measurements, and surface examinations. Alternating current accelerates the dissolution of zinc significantly but reduces the corrosion rate of pipeline steel. Under an applied alternating current, zinc DC potential shifts negatively while the DC potential shift direction of pipeline steel is closely related to the value of alternating current density. When the alternating current density is low the DC potential shifts negatively. It, however, shifts positively under higher alternating current density. Besides, the coupling current increases with alternating current density.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.