Amperometric biosensors were developed on the basis of stationary mercury-film and glassy-carbon electrodes and DNA or its fragments, oligodeoxynucleotides (ODNs), immobilized in a nitrocellulose matrix. Taking into account the high affinity of Cu(II) and Fe(III) ions to denatured DNA ((19.1 ± 0.1) ×105 and (1.4 ± 0.3) × 105 L/mol, respectively), a procedure was proposed for the voltammetric determination of these ions in natural materials and blood serum at a level of n × 10−11 M. This procedure involves analyte pre-concentration on a DNA-containing biosensor. An ODN-containing biosensor (DNA probe) was used in the study of DNA hybridization for the highly specific determination of its nucleotide sequence.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.