Abstract

Ractopamine (RAC) is an important β-agonist. It improves the growth rate and reduces the fat for animals. It is also utilized as nutrient repartitioning agent. Nonetheless, it is not licensed in many countries and RAC is dangerous for human health when it is used illegally. Thus, the development of the sensitive analytical methods for real samples is crucial. Carbon nitride nanotubes (C3N4NTs)/ionic liquid (ILs) nanocomposite was firstly synthesized for RAC detection in this study. n-hexyl-3-methylimidazolium hexafluoro phosphate was used as ionic liquid. The formation of the surfaces was characterized by scanning electron microscope (SEM), electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and x-ray photoelectron spectroscopy (XPS). The linearity range and the detection limit (LOD) for RAC were calculated as 1.0 × 10−9–1.0 × 10−12 M and 1.0 × 10−13 M, respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.