Abstract

Removal of selenate from solution is investigated in batch electrochemical systems using reactive iron anodes and copper plate cathode in a bicarbonate medium. Iron anodes produce ferrous hydroxide, which is a major factor in the removal of selenate from solution. Iron anodes also generate a significant decrease in the oxidation–reduction potential (ORP) of the solution because it prevents generation of oxygen gas at the anode by electrolysis. The removal rates varied from 45.1% to 97.4%, depending on current density and selenate concentration. The transformation of selenate by the process is modeled based on a heterogeneous reaction coupled with electrochemical generation of ferrous and hydroxide. The rates are optimized at lower initial concentrations, higher electrical currents, and the presence of anions. Presence of dissolved oxygen does not cause any significant effects the removal of selenate.