Abstract

Li-ion cells are used in a variety of mobile and stationary applications. Their use must be safe under all conditions, even for aged cells in second-life applications. In the present study, different aging mechanisms are taken into account for accelerating rate calorimetry (ARC) tests. 18650-type cells are cycled at 0°C (Li plating expected) and at 45°C (SEI growth expected). After extensive evaluation of the electrochemical results (voltage curve analysis, capacity fade, energy fade, Coulombic efficiency), the cells are tested by Post-Mortem analysis (CT, GD-OES, SEM) to reveal the main aging mechanisms and by ARC to test the safety behavior. Besides typical ARC results such as onset-of-self-heating, onset-of-thermal runaway and maximum temperatures, as well as acoustic responses of thermal runaway are evaluated and a method is developed to compare fresh cells and cells aged until different SOHs. It turns out that the safety of aged cells is not simply a function of the SOH. However, safety is strongly affected by the main aging mechanism and to the history of operating parameters during the life-time of the cell. Unsafe behavior is indicated by certain features in the voltage curves.