Abstract

LiCo1/3Ni1/3Mn1/3O2 cathode electrodes were prepared onto Al current collectors with different surface morphologies through usual doctor blade technique. Their electrochemical performances, especially at high current rate, were influenced by the surface morphology of the current collector:. These implied the less polarization for the electrode prepared on the surface roughened current collector. In addition, the AC complex impedance analysis exhibited that the interface resistance between the film electrode and the current collector as well as the interface resistance between the electrode and the electrolyte was reduced in the case of the surface-roughened current collector, but that the Ohmic resistance was enlarged.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.