• Electrochemical noise was used to evaluate the localized corrosion of PP-based NCCs. • PP|Graft|GO = 0.1 illustrated the best localized corrosion performance. • PP|Graft|GO = 0.1 was able to re-passive and prevent the growth of large & deep pits. • In the presence of GO, the transients shift to the higher frequencies at all times. Electrochemical noise analysis was applied to evaluate the localized anti-corrosion performance of polypropylene (PP)-based nanocomposite coatings (NCC). In this regard, the NCCs were developed on mild steel from a solution containing PP, MAH-grafted PP, and different percentages of graphene oxide (GO). The coated samples were subjected to thermal tests, salt spray, and electrochemical noise (EN) analysis. Electrochemical potential and current noise (EPN & ECN) signals were evaluated to find information about localized corrosion. First, the raw signals were analyzed based on the empirical mode decomposition (EMD), then the 3D diagrams (intensity, time, and frequency) were plotted using the Hilbert transform. The results showed in the presence of GO, the transients shift to the higher frequencies at all times, which confirms more tendency to uniform corrosion instead of localized. Introducing 3 wt% of GO NPs into the coating leads to the electrochemical noise resistance increasing by 5 times (>10 8 Ω.cm 2 ), pit initiation rate decreasing, and pit radius reduction (by ∼5 times). As a result, MAH-grafted PP and GO in these NCCs can act as effective barriers against corrosive agents, especially the agents that cause pitting corrosion.