Abstract
Temozolomide (TMZ) is an anticancer drug used for the treatment of adult brain tumour and skin cancer. The biomolecular interaction between TMZ and DNA was investigated for the first time in this study using disposable pencil graphite electrodes (PGEs) in combination with electrochemical techniques. The surface confined interactions between TMZ and different type of nucleic acids were performed. Before/after surface confined interaction process, the oxidation signals of TMZ, guanine and adenine were measured using differential pulse voltammetry (DPV) and PGE and accordingly, the changes at the oxidation signals were evaluated. The detection limit (DL) was also estimated based on the oxidation signal of TMZ. The interaction of TMZ with single stranded poly [A], poly [G], or double stranded poly [A]-poly[T] and poly [G]-poly[C] was also explored. Moreover, cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) techniques were utilized for detection the interaction between TMZ and DNA. The features of this single-use electrochemical sensor was discussed in comparison to other reports that were developed for TMZ detection.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.