Abstract

Two kinds of chemically modified electrodes were prepared. In the first type of electrodes, zinc oxide (ZnO) and flavin adenine dinucleotide (FAD) molecules were deposited onto the glassy carbon-, gold-, and SnO2-coated glass electrodes by using cyclic voltammetry from the bath solution containing aqueous 0.1 M zinc nitrate, 0.1 M sodium nitrate, and 1 × 10−4 M FAD. It was called as ZnO/FAD modified electrodes. The second type of modified electrode was prepared by the electropolymerization method. Electrochemical polymerization of FAD was carried out from the acidic solution containing 1 × 10−4 M FAD monomers onto electrode surfaces. This poly(FAD)-modified electrode yields a new redox couple in addition to the monomers redox couple. The influence of the concentrations, pH, and electrocatalytic properties of the ZnO/FAD- and poly(FAD)-modified electrodes are investigated by means of the in situ technique electrochemical quartz–crystal microgravimetry (EQCM) combined with cyclic voltammetry and the ex situ technique scanning electron microscopy. From these studies, it appears that the cathodic deposition of ZnO/FAD-modified electrodes gives only one redox couple, and the anodically polymerized FAD film-modified electrodes gives two reversible redox couples. The pH dependence of the redox responses were investigated and the kinetics of electron transfer was evaluated. In addition, the EQCM technique was employed to follow the deposition process of both kinds of modified electrodes in real time as well as the characteristics of the charge transfer associated with the surface-confined redox-active couples. The electrocatalytic activity of the poly(FAD)-modified electrode towards the reduction of hydrogen peroxide and the oxidation of dopamine and ascorbic acid was explored. The important electrocatalytic properties of poly(FAD)-modified electrode were observed for simultaneous separation of dopamine and ascorbic acid in neutral solution. This poly(FAD)-modified electrode has several advantages than the previously reported FAD-modified electrodes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.