Abstract

The solubility of oxygen in liquid lead bismuth eutectic (LBE) was determined by using electrochemical methods. The oxygen partial pressure in oxygen saturated LBE was measured from 475 to 724 K by using an oxygen sensor comprised of yttria partially stabilized zirconia and air/LSM (Lanthanum strontium manganite) reference electrode. Sieverts’ constant of the dissolved oxygen in LBE was measured from 598 to 748 K by coulometric titration method using the oxygen sensor. The measured oxygen partial pressure in oxygen saturated LBE (in bar) and Sieverts’ constant of dissolved oxygen in LBE (k for a 1 wt% standard state) are given by (475–724 K), log k = 3.12 − 7072/T (598–748 K) respectively. Combining the measured data, the oxygen solubility in LBE (CO, S in wt%) was derived and is given by log CO, S = 2.64 − 4426/T (598–724 K).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.