Abstract
ABSTRACT The performance of simultaneous electro oxidation of epinephrine (EP) and folic acid (FA) was achieved at allopurinol polymerised carbon paste electrode (AlpM-CPE) by cyclic voltammetry (CV) method at physiological pH. The modified electrode showed remarkable sensing activity towards the electrooxidation of EP, involving irreversible 2-electronstransfer with adsorption-controlled kinetics. The results of varying few experimental parameters, for instance – scan rate, solution pH, concentration of the target analyte was examined. It was observed that, the anodic peak current (Ipa) is proportional to the concentration of EP in the range 51.02–318.18 μM with a calculated limit of detection (LOD) 0.46 µM by CV technique. The analytical applicability of the fabricated AlpM-CPE was examined for the resolve of EP in pharmaceutical sample and a good recovery results were observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.