Abstract

Formation of porous TiOx layers on Ti during electrochemical etching in H3PO4, CH3COOH electrolytes modified by HF and NH4F was described. The anodization resulted in porous TiOx formation, useful in tissue growth and bone bonding. The pore dimensions increased due to the increase of HF or NH4F content in H3PO4 electrolyte. During anodization at 10 V for 30 min, when the HF content increased from 0.5 to 10%, the pore diameter increased from 30 nm up to 8 m, respectively. Anodization in CH3COOH electrolyte resulted in non-uniform etching with flat hexagonal islands with nanopores inside surrounded by micropores. Corrosion properties of the etched samples were investigated in Ringer’s solution at 37oC and were compared to the unetched sample. The best corrosion resistance showed the samples etched at 10 V for 30 min in 1M H3PO4 + 2% HF and 1M H3PO4 + 10% NH4F, what can be attributed to thick oxide layer. We find, that porous sample presented good biocompatibility with human osteoblasts.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.