Abstract

An electrochemical disinfection system employing a honeycombed platinum coated titanium electrode was developed for the disinfection of seawater. Cell suspensions (2 l, 10³ cells/ml) of the fish pathogens, Vibrio alginolyticus, Edwardsiella tarda, Lactococcus garvieae and Vibrio anguillarum were circulated in a reactor equipped with 10 sets of these electrodes at a flow rate of 200 ml/min with an applied potential of 1.0 V vs. Ag/AgCl reference electrode. The circulated cells were completely disinfected after 3 h of treatment, whereas free residual chlorine generated due to seawater electrolysis was below 0.1 ppm. In addition, a diphenyl-1-pyrenylphosphine fluorescent assay revealed that lipid peroxidation in the cell membranes of disinfected bacteria was induced probably by reactive oxygen species generated during electrochemical treatment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.