Abstract
Employing a graphene-modified glassy carbon electrode, a sensitive and convenient electrochemical method for the determination of phoxim by linear sweep voltammetry was developed. The electrochemical behavior of phoxim at the modified electrode was studied by cyclic voltammetry. In citric acid–phosphate buffers, the modified electrode exhibited excellent electrocatalytical effect on the reduction of phoxim and this was further used for the determination of phoxim. Under optimized analytical conditions, the reduction peak current showed a linear relationship with the concentration of phoxim in a range of 5.97 to 5,966 μg L−1, with a correlation coefficient of 0.9993 and a detection limit of 2.39 μg L−1. The proposed method shows excellent sensitivity, selectivity, and linearity and has been successfully applied for the determination of phoxim in a variety of food samples with satisfactory results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.