Abstract
EP is an important natural catecholamine neurotransmitter in the central nervous system, and the change of EP concentration will lead to many diseases. Therefore, rapid and sensitive detection of EP is of great significance for clinical research. The Ti3C2Tx MXene dispersion obtained by in-situ HF etching Ti3AlC2 was mixed with graphene oxide (GO) dispersion synthesized by the modified Hummers method. After freeze drying and heat-treatment, the reduced graphene oxide/Ti3C2Tx MXene (GMA) was obtained and then the GMA was moved onto indium tin oxide (ITO) as the GMA/ITO working electrode for electrochemical detection of epinephrine (EP). The results are as follows: Ti3C2Tx MXene with a diameter of approximately 150 nm is uniformly distributed on the surface of the 3D graphene. The three-dimensional structure of GMA facilitates the entry of bioactive molecules and increases the contact area. GMA/ITO has a high sensitivity for the determination of EP 3.74 μA·μM−1·cm−2. Moreover, the electrode shows a very low detection limit, well repeatability and stability, and it can detect the EP content in real urine samples.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.