Abstract
This paper aims to evaluate the efficiency of the electrochemical chloride extraction technique and its impact in concrete contaminated with 1% of chloride by monitoring chloride content, specific porosity, water absorption and corrosion potential, verifying the influence of variables reinforcement cover (1.0 and 3.0cm) and water/cement ratio (0.43 and 0.59). Results show that the concrete needs additional protection after chlorides extraction in order to prevent recontamination, since the porosity of the concrete increases with the application of the electrochemical chloride extraction. Average pore diameter increased 78% and 42% for concretes with w/c of 0.59 and 0.43, allowing the ingress of aggressive agents.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.