Abstract

AbstractThe characterization of corrosion products in leaded bronze based on the voltammetry of immobilized particles methodology is described. Voltammetric data, supported by Fourier transform infra‐red spectroscopy, field emission scanning electron microscopy‐energy dispersive X‐ray microanalysis (FESEM‐EDX) and scanning electrochemical microscopy (SECM) allow the identification of copper and lead corrosion materials. The mutual influence of such products is modeled upon considering uncompensated ohmic drops in the Tafel analysis of the rising portion of the respective voltammetric signals for their electrochemical reduction.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have