Abstract
Metal hydride electrodes with copper-encapsulated alloys and non-coated alloys were fabricated using suitable conductive and binding agents. The charge-discharge characteristics of three kinds of hydride electrodes were comparatively investigated. The encapsulated alloy electrode is remarkably superior to the non-coated LaNi 5-based one, discharging at a high rate and exhibiting a smaller capacity decay at the stage of cycle tests. The hydride alloy quality of hydride electrodes can be effectively determined by measuring rate capability. The results of vented cell experiments confirm that the capacity decay of non-coated alloy electrodes in sealed cells is not due to the oxidation of oxygen from the nickel hydroxide positive electrodes. The relationship between the equilibrium potential of hydride electrode and the equilibrium hydrogen pressure has been deduced by a succinct thermodynamic method, without consideration of the unknown activity of water and fugacity coefficient of hydrogen.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.